%0 Journal Article %K traumatic reticuloperitonitis %K cow %K radiography %K x-ray beam-limitingcone %K diagnostic imaging %B Berliner und Münchener Tierärztliche Wochenschrift %C Hannover %D 2009 %G English %I M. & H. Schaper GmbH %P 429-435 %R 10.2376/0341-6593-116-429 %T Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis %V 116 %1 {"oldId":70965,"title":"Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis","teaserText":"To evaluate the quality and the diagnostic relevance of the radiographs of thereticular area obtained using an x-ray beam-limiting cone (LC), both conventionaland LC images were analysed in 12 cows affected by traumatic reticuloperitonitis(TRP)....","content":"

Summary<\/span>
To evaluate the quality and the diagnostic relevance of the radiographs of thereticular area obtained using an x-ray beam-limiting cone (LC), both conventionaland LC images were analysed in 12 cows affected by traumatic reticuloperitonitis(TRP). The improvement in resolution, definition and contrast of the LC imagesand a clinical assessment of the diagnostic relevance of the procedure werescored. The use of LC improved the quality of the radiographs in 10 cases (83%)thanks to an improvement in the resolution (67%), definition (58%) and contrast(83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating thedetection of details not clearly visualised by previous conventional survey radiographs:a very thin foreign body responsible of TRP, a mass in the ventro-caudalcontour of the reticulum, the exact position of the foreign bodies. A consistencytest for the x-rays was performed in a clinically healthy cow to confirm theimprovement in the radiographic quality determined by the procedure. Althoughconventional imaging is often sufficient to confirm diagnosis of TRP, the use ofthe LC improves the quality of reticular radiographs and in several cases can befundamental for the identification of a thin foreign body or a lesion.

Keywords:<\/span>
traumatic reticuloperitonitis, cow, radiography, x-ray beam-limitingcone, diagnostic imaging


Zusammenfassung<\/span>
Zur Evaluierung der Qualit\u00e4t sowie der diagnostischen Aussagekraft vonR\u00f6ntgenaufnahmen der Haubengegend mittels R\u00f6ntgenstrahlfokussierungdurch einen kegelf\u00f6rmigen Strahlentunnel (LC) wurden konventionelle und LCR\u00f6ntgenbildervon 12 K\u00fchen mit Reticuloperitonitis traumatica (TRP) analysiert.Bewertet wurden die Verbesserung von Aufl\u00f6sung, Bildsch\u00e4rfe und Kontrast derLC-Aufnahmen sowie die klinische Relevanz dieses Verfahrens. Die Anwendungder LC-Aufnahmetechnik erh\u00f6hte in 10 F\u00e4llen (83 %) die Qualit\u00e4t der R\u00f6ntgenaufnahmenaufgrund einer Verbesserung von Aufl\u00f6sung (67 %), Bildsch\u00e4rfe (58 %)und Kontrast (83 %). Das Verfahren war in 5 F\u00e4llen (42 %) diagnostisch relevant,da hiermit die radiologische Beurteilung von Details, welche in den vorherigenkonventionellen R\u00f6ntgenaufnahmen nicht deutlich dargestellt werden konnten,erm\u00f6glicht wurde. Hierzu geh\u00f6rten die Darstellung eines sehr d\u00fcnnen Fremdk\u00f6rpers,welcher f\u00fcr die TRP verantwortlich war, einer Umfangsvermehrung inder ventro-caudalen Haubenwand sowie die Darstellung der exakten Positionder Fremdk\u00f6rper. Zur \u00dcberpr\u00fcfung der Ergebnisse wurden R\u00f6ntgenaufnahmenvon einer klinisch gesunden Kuh angefertigt, um die Verbesserung der R\u00f6ntgenbildqualit\u00e4tdurch das LC-Verfahren zu best\u00e4tigen. Obwohl eine konventionelleAufnahme h\u00e4ufig ausreicht, um die Diagnose TRP zu best\u00e4tigen, verbessert dieAnwendung der LC-Technik die Qualit\u00e4t der Haubenaufnahmen und kann ineinigen F\u00e4llen, von entscheidender diagnostischer Bedeutung sein.

Schl\u00fcsselw\u00f6rter:<\/span>
Reticuloperitonitis traumatica, Kuh, Radiologie, R\u00f6ntgenstrahlfokussierung,bildgebende Diagnostik<\/p>","categories":["Tier\u00e4rztliche Wochenschrift","Abostufe BMTW","Fachartikel"],"fromDate":"Dec 3, 2009 12:00:00 AM","toDate":"Dec 31, 2050 12:00:00 AM","oldUrls":["http:\/\/vetline.de\/traumatic-reticuloperitonitis-cow-radiography-x-ray-beam-limiting\/150\/3130\/70965"],"doiLanguage":"englisch","doiProductFormat":"Online","doiPublisher":"M. & H. Schaper GmbH","doiSerialWorkTitle":"Dtsch.tier\u00e4rztl.Wschr.","doiDocumentUri":"http:\/\/www.vetline.de\/traumatic-reticuloperitonitis-cow-radiography-x-ray-beam-limiting\/150\/3130\/70965","doiSource":"Dtsch.tier\u00e4rztl.Wschr. 116: 12, 429-435 (2009)","doiissn":"0341-6593","doiNr":"10.2376\/0341-6593-116-429","doiFirstPage":"429","doiLastPage":"435","doiTransmitted":true,"doiAuthor":"Pravettoni D, Zani DD, Biggi M, Morandi N, Di Giancamillo M, Bertagnoli A, Belloli AG","pdf":{"path":"http:\/\/data\/dtw_2009_12_0429.pdf","title":"dtw_2009_12_0429.pdf","description":"Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis

"},"authors":[{"firstName":"D","middleName":"","lastName":"Pravettoni"},{"firstName":"D","middleName":"D","lastName":"Zani"},{"firstName":"M","middleName":"","lastName":"Biggi"},{"firstName":"N","middleName":"","lastName":"Morandi"},{"firstName":"M","middleName":"","lastName":"Di Giancamillo"},{"firstName":"A","middleName":"","lastName":"Bertagnoli"},{"firstName":"A","middleName":"G","lastName":"Belloli"}],"contentOptimised":"

Summary<\/strong>
To evaluate the quality and the diagnostic relevance of the radiographs of thereticular area obtained using an x-ray beam-limiting cone (LC), both conventionaland LC images were analysed in 12 cows affected by traumatic reticuloperitonitis(TRP). The improvement in resolution, definition and contrast of the LC imagesand a clinical assessment of the diagnostic relevance of the procedure werescored. The use of LC improved the quality of the radiographs in 10 cases (83%)thanks to an improvement in the resolution (67%), definition (58%) and contrast(83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating thedetection of details not clearly visualised by previous conventional survey radiographs:a very thin foreign body responsible of TRP, a mass in the ventro-caudalcontour of the reticulum, the exact position of the foreign bodies. A consistencytest for the x-rays was performed in a clinically healthy cow to confirm theimprovement in the radiographic quality determined by the procedure. Althoughconventional imaging is often sufficient to confirm diagnosis of TRP, the use ofthe LC improves the quality of reticular radiographs and in several cases can befundamental for the identification of a thin foreign body or a lesion.

Keywords:<\/strong>
traumatic reticuloperitonitis, cow, radiography, x-ray beam-limitingcone, diagnostic imaging


Zusammenfassung<\/strong>
Zur Evaluierung der Qualit\u00e4t sowie der diagnostischen Aussagekraft vonR\u00f6ntgenaufnahmen der Haubengegend mittels R\u00f6ntgenstrahlfokussierungdurch einen kegelf\u00f6rmigen Strahlentunnel (LC) wurden konventionelle und LCR\u00f6ntgenbildervon 12 K\u00fchen mit Reticuloperitonitis traumatica (TRP) analysiert.Bewertet wurden die Verbesserung von Aufl\u00f6sung, Bildsch\u00e4rfe und Kontrast derLC-Aufnahmen sowie die klinische Relevanz dieses Verfahrens. Die Anwendungder LC-Aufnahmetechnik erh\u00f6hte in 10 F\u00e4llen (83 %) die Qualit\u00e4t der R\u00f6ntgenaufnahmenaufgrund einer Verbesserung von Aufl\u00f6sung (67 %), Bildsch\u00e4rfe (58 %)und Kontrast (83 %). Das Verfahren war in 5 F\u00e4llen (42 %) diagnostisch relevant,da hiermit die radiologische Beurteilung von Details, welche in den vorherigenkonventionellen R\u00f6ntgenaufnahmen nicht deutlich dargestellt werden konnten,erm\u00f6glicht wurde. Hierzu geh\u00f6rten die Darstellung eines sehr d\u00fcnnen Fremdk\u00f6rpers,welcher f\u00fcr die TRP verantwortlich war, einer Umfangsvermehrung inder ventro-caudalen Haubenwand sowie die Darstellung der exakten Positionder Fremdk\u00f6rper. Zur \u00dcberpr\u00fcfung der Ergebnisse wurden R\u00f6ntgenaufnahmenvon einer klinisch gesunden Kuh angefertigt, um die Verbesserung der R\u00f6ntgenbildqualit\u00e4tdurch das LC-Verfahren zu best\u00e4tigen. Obwohl eine konventionelleAufnahme h\u00e4ufig ausreicht, um die Diagnose TRP zu best\u00e4tigen, verbessert dieAnwendung der LC-Technik die Qualit\u00e4t der Haubenaufnahmen und kann ineinigen F\u00e4llen, von entscheidender diagnostischer Bedeutung sein.

Schl\u00fcsselw\u00f6rter:<\/strong>
Reticuloperitonitis traumatica, Kuh, Radiologie, R\u00f6ntgenstrahlfokussierung,bildgebende Diagnostik<\/p>","primaryLanguage":"englisch","summary":"To evaluate the quality and the diagnostic relevance of the radiographs of thereticular area obtained using an x-ray beam-limiting cone (LC), both conventionaland LC images were analysed in 12 cows affected by traumatic reticuloperitonitis(TRP). The improvement in resolution, definition and contrast of the LC imagesand a clinical assessment of the diagnostic relevance of the procedure werescored. The use of LC improved the quality of the radiographs in 10 cases (83%)thanks to an improvement in the resolution (67%), definition (58%) and contrast(83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating thedetection of details not clearly visualised by previous conventional survey radiographs:a very thin foreign body responsible of TRP, a mass in the ventro-caudalcontour of the reticulum, the exact position of the foreign bodies. A consistencytest for the x-rays was performed in a clinically healthy cow to confirm theimprovement in the radiographic quality determined by the procedure. Althoughconventional imaging is often sufficient to confirm diagnosis of TRP, the use ofthe LC improves the quality of reticular radiographs and in several cases can befundamental for the identification of a thin foreign body or a lesion.","keywords":["traumatic reticuloperitonitis","cow","radiography","x-ray beam-limitingcone","diagnostic imaging"],"zusammenfassung":"Zur Evaluierung der Qualit\u00e4t sowie der diagnostischen Aussagekraft vonR\u00f6ntgenaufnahmen der Haubengegend mittels R\u00f6ntgenstrahlfokussierungdurch einen kegelf\u00f6rmigen Strahlentunnel (LC) wurden konventionelle und LCR\u00f6ntgenbildervon 12 K\u00fchen mit Reticuloperitonitis traumatica (TRP) analysiert.Bewertet wurden die Verbesserung von Aufl\u00f6sung, Bildsch\u00e4rfe und Kontrast derLC-Aufnahmen sowie die klinische Relevanz dieses Verfahrens. Die Anwendungder LC-Aufnahmetechnik erh\u00f6hte in 10 F\u00e4llen (83 %) die Qualit\u00e4t der R\u00f6ntgenaufnahmenaufgrund einer Verbesserung von Aufl\u00f6sung (67 %), Bildsch\u00e4rfe (58 %)und Kontrast (83 %). Das Verfahren war in 5 F\u00e4llen (42 %) diagnostisch relevant,da hiermit die radiologische Beurteilung von Details, welche in den vorherigenkonventionellen R\u00f6ntgenaufnahmen nicht deutlich dargestellt werden konnten,erm\u00f6glicht wurde. Hierzu geh\u00f6rten die Darstellung eines sehr d\u00fcnnen Fremdk\u00f6rpers,welcher f\u00fcr die TRP verantwortlich war, einer Umfangsvermehrung inder ventro-caudalen Haubenwand sowie die Darstellung der exakten Positionder Fremdk\u00f6rper. Zur \u00dcberpr\u00fcfung der Ergebnisse wurden R\u00f6ntgenaufnahmenvon einer klinisch gesunden Kuh angefertigt, um die Verbesserung der R\u00f6ntgenbildqualit\u00e4tdurch das LC-Verfahren zu best\u00e4tigen. Obwohl eine konventionelleAufnahme h\u00e4ufig ausreicht, um die Diagnose TRP zu best\u00e4tigen, verbessert dieAnwendung der LC-Technik die Qualit\u00e4t der Haubenaufnahmen und kann ineinigen F\u00e4llen, von entscheidender diagnostischer Bedeutung sein.","schluesselwoerter":["Reticuloperitonitis traumatica","Kuh","Radiologie","R\u00f6ntgenstrahlfokussierung","bildgebende Diagnostik"],"translatedTitle":"","abstractE":"To evaluate the quality and the diagnostic relevance of the radiographs of thereticular area obtained using an x-ray beam-limiting cone (LC), both conventionaland LC images were analysed in 12 cows affected by traumatic reticuloperitonitis(TRP)....","date":{"year":2009,"date":"12\/2009","accepted":"2009-12-03"},"volume":"116","openAccess":false,"journal":"Berliner und M\u00fcnchener Tier\u00e4rztliche Wochenschrift","titleImageId":944,"pages":"429-435","redirects":["traumatic-reticuloperitonitis-cow-radiography-x-ray-beam-limiting\/150\/3130\/70965"],"tierartCategories":[],"artikelartCategories":["Tier\u00e4rztliche Wochenschrift","Abostufe BMTW","Fachartikel"]} %8 12/2009